How to Plan Pile and Shaft Installation Monitoring

· Gulf South Engineering and Testing

By Gulf South Engineering and Testing

Deep foundations are built where you cannot see them. Monitoring and load testing during installation are how an owner knows the piles and drilled shafts in the ground match the design. This guide covers what to plan before the first pile goes in.

1. Know which foundation types you have

Monitoring differs for driven piles, augercast piles and drilled shafts. Gulf South's CONSTRUCTION MATERIALS TESTING page lists pile (driven and augercast) and shaft installation monitoring, and pile and shaft load tests.

2. Decide which load tests the project needs

Your foundation design and specifications set the tests. Two standardized methods are common:

  • Static axial compression load test, ASTM D1143/D1143M. These test methods "measure the axial deflection of an individual vertical or inclined deep foundation element or group of elements when loaded in static axial compression," and apply to drilled shafts, cast-in-place piles including augered cast-in-place piles, and driven piles (ASTM D1143/D1143M, section 1.1).
  • High-strain dynamic test, ASTM D4945. This method covers "applying an axial impact force with a pile driving hammer or a large drop weight that will cause a relatively high strain at the top of an individual vertical or inclined deep foundation unit, and for measuring the subsequent force and velocity response" (ASTM D4945, section 1.1).

Ask your geotechnical engineer which tests, how many, and on which elements.

3. Plan the installation record

Monitoring means an inspector watches and records each element as it goes in. Agree before work starts on what the inspector records, the form it is recorded on, and who receives it each day.

4. Plan for nearby structures

Pile driving makes vibration and noise. Gulf South's CMT page lists vibration monitoring, noise monitoring, and pre- and post-construction inspection, which document neighboring buildings before and after the work.

5. Agree how problems are escalated

Decide who the inspector calls when an element does not match the design criteria, and who decides what happens next.

Questions to ask your testing firm

  1. Which foundation types have you monitored, and which load tests have you run?
  2. Which test standard will each load test follow?
  3. What does your daily installation record include, and when do we receive it?
  4. Do you provide vibration and noise monitoring and pre-construction inspections?
  5. Who on your team reviews installation data with our geotechnical engineer?

Frequently asked questions

What is a static load test?

A test that measures how much a deep foundation element moves under static axial compression load; ASTM D1143/D1143M describes the methods.

What is a high-strain dynamic test?

A test that strikes the top of a pile with a hammer or drop weight and measures the force and velocity response; ASTM D4945 describes the method.

Does monitoring apply to augercast piles and drilled shafts?

Yes. Gulf South monitors driven and augercast piles and shafts, and ASTM D1143/D1143M applies to drilled shafts and augered cast-in-place piles as well as driven piles.

Why monitor vibration?

To document effects on neighboring structures; Gulf South provides vibration and noise monitoring and pre- and post-construction inspections.